Skip to content
CNC Bike Parts

Verifying 7075-T73 on Finished Bike Parts: Conductivity and Hardness

Published November 28, 2026. Checked October 2026.

7075-T6 and 7075-T73 cannot be told apart by eye. T73 is over-aged and conducts better: a public inspection manual lists 30 to 35 percent IACS for T6 and 38 to 42.5 for T73. An eddy current reading plus a hardness check on the finished part confirms the temper after machining. It supports the mill certificate and does not replace it.

Temper Conductivity, % IACS (public manual ranges) Single values in handbook listings What the temper is
7075-T6XX 30.0 to 35.0 33.0 (one listing), 31.4 to 34.8 (another) Peak aged, highest strength
7075-T76X 36.0 to 39.0 38.5 Between T6 and T73
7075-T73X 38.0 to 42.5 40.0 Over-aged, resists stress corrosion cracking
7075-O 44.0 to 48.0 not listed Annealed

As of October 2026. The ranges come from a public US Army nondestructive inspection manual and are meant for sorting temper, not for acceptance. Acceptance limits live in the specification on your drawing and differ by specification and revision.

Number line of electrical conductivity in percent IACS with bands for 7075 T6, T76 and T73 and a gap between T6 and T73
Typical conductivity bands. The gap between T6 and T73 is where a mixed-up bar shows up.

Why conductivity separates the tempers

Conductivity of an aluminum alloy depends on how much alloying element sits in solid solution and on the precipitates in the metal. Aging precipitates the elements out, and as aging passes the peak, hardness falls while conductivity keeps rising. T73 is aged past the peak, so it conducts better and is softer than T6. The same article that explains this recommends measuring both hardness and conductivity, since either one alone can be ambiguous on the hardness and conductivity loop.

For bike parts the point is practical. The T6 versus T73 article explains why a press-fitted sleeve or thick bolted section may be drawn in T73. Strength drops by roughly a tenth. A bar of the wrong temper looks the same, machines the same and fits the same. A conductivity meter is how you find out.

How the measurement is done

Conductivity of nonmagnetic metals is measured with an eddy current instrument. ASTM E1004 is the test method for it. It is written mainly for direct-reading conductivity instruments, covers flat or slightly curved surfaces and reports results in percent IACS, where 100 percent is the conductivity of annealed copper at 20 degrees C. Three points matter on a finished part.

  1. Calibration. Eddy current meters need reference standards of known conductivity. The record should name the standards or block serial numbers and the date of calibration.
  2. Surface. Use a flat, clean face wider than the probe and away from edges and holes. Small round bike parts, such as axles and spindles, need a flat or a probe made for curved surfaces. Say where the reading was taken.
  3. Condition of the part. Temperature and surface coating change the reading. ASTM E1004 allows a thin non-conductive coating, but take the reading before anodizing where possible, and say so.

Hardness is read on a Rockwell B tester or an equivalent. It confirms what conductivity suggests, and it detects a part that was heated after leaving the mill. For aerospace work, hardness and conductivity acceptance criteria for finished or semi-finished wrought aluminum parts sit in SAE AMS 2658. For bike parts you are not bound to it, but a drawing that cites it gives the shop a defined target. Check which revision your drawing cites.

Reading the result

Reading Probable cause Action
Inside the T73 band, hardness lower than T6 Correct temper File the reading with the lot record
Inside the T6 band on a part drawn T73 Wrong bar or wrong temper supplied Quarantine the lot, compare lot marks and the mill certificate
Between 35 and 38 percent IACS Ambiguous: T76, a partly aged part or a measurement problem Remeasure with calibrated meter, compare hardness, ask the mill
Inside T73 band, hardness high Part heated or aged out of sequence Review the process route with the shop
Reading varies from face to face Poor contact, curved surface, coating or edge effect Take three readings on a flat bare face and record the mean

Do not use the table above to accept a part. It sorts parts by temper. Acceptance is against the specification the drawing cites.

What conductivity does not prove

Resistance to stress corrosion cracking is tested on product samples with methods such as ASTM G47, an alternate immersion test in 3.5 percent sodium chloride solution. Product specifications for T73 bar carry their own stress corrosion requirements, so read the one on your drawing. A conductivity check on a finished part shows it is in the right aging range. It does not show that the part passes G47, and it does not show strength. Strength comes from tensile tests on the bar, listed on the mill certificate. Read conductivity together with hardness and the certificate, never alone.

Matching the certificate to the part

The mill certificate says what the bar was, not what the part is. Three controls close the gap.

  • Lot marking. The bar lot or heat code travels with the work order and appears on the first article report. The traceability article shows a marking route.
  • A reading per lot. Take a conductivity reading on the first part from each bar, record it with the lot and keep the record.
  • Heat after the mill. Weld repair, hot forming and any other high-temperature step can change the temper. A part that went through such a step needs a new reading.

Bar is usually bought to ASTM B211 or an aerospace specification such as AMS 4124 for 7075-T73 and T7351. The alloy reference lists common alloys with sources. See also first article inspection for bike parts.

What to write on the drawing

MATERIAL: 7075-T7351 BAR PER [SPEC AND REVISION]. MILL CERTIFICATE WITH LOT NUMBER REQUIRED.
VERIFY TEMPER BY EDDY CURRENT CONDUCTIVITY PER ASTM E1004 ON THE FIRST PART OF EACH BAR.
RECORD READING IN PERCENT IACS, INSTRUMENT AND REFERENCE STANDARD. ACCEPTANCE PER THE SPECIFICATION.

Replace the brackets with the specification your customer uses. If the drawing states only “7075”, expect T6 and read material call-outs on a drawing. Put the verification step in the RFQ so the quote includes the instrument and the time.

A note on this site. We do not test materials, issue certificates or hold accreditation. Conductivity ranges here come from public manuals and are not acceptance limits. Read the limits in the specification on your drawing and ask your shop for readings with instrument and calibration data.

Frequently asked questions

Does a good conductivity reading prove stress corrosion resistance?

No. Conductivity is a fast proxy for the aging condition. The stress corrosion test, ASTM G47, is an alternate immersion test in 3.5 percent salt solution run on product samples. A conductivity pass tells you the part is in the T73 range, which is where the resistance comes from. It does not replace the product test behind the mill certificate.

Can the shop measure through the anodize?

ASTM E1004 is written for surfaces with or without a thin non-conductive coating, but thickness and probe change the reading. Ask for readings taken before anodizing on the bare part, or on a masked or stripped spot, and for the method to be stated.

How many parts need a reading?

The test is quick, so the question is a lot rule rather than cost. Agree it in writing: for example every part from a safety-critical lot, or a stated number per bar. We do not publish a sampling number, because the right one depends on the part and the brand's risk.

What if the reading falls between T6 and T73?

Treat it as a reject until resolved. A reading between the bands, such as 36 percent IACS, can come from the wrong temper, from heat exposure after the bar left the mill, from an uncalibrated meter or from a poor probe contact. Remeasure with a calibrated meter on a flat face, then check the mill certificate and the lot mark.

Sources

  1. TM 1-1500-335-23 Nondestructive Inspection Methods Manual, Table 4-7, electrical conductivity ranges for aluminum alloys (7075-T6XX, T73X, T76X) chemical-biological.tpub.com
  2. NDT Supply, conductivity reference chart for aluminum alloys (ASM Handbook and instrument listings) content.ndtsupply.com
  3. D. Scott MacKenzie, Heat treatment of aluminum, part VII: hardness and conductivity (Thermal Processing, April 2021) thermalprocessing.com
  4. ASTM E1004, determining electrical conductivity using the electromagnetic (eddy current) method (ASTM catalogue) store.astm.org
  5. ASTM G47, determining susceptibility to stress-corrosion cracking of 2XXX and 7XXX aluminum alloy products (ANSI catalogue) webstore.ansi.org
  6. ASTM B211/B211M-23, aluminum bar, rod and wire (ASTM catalogue, tempers include T73 and T7351) store.astm.org
  7. SAE AMS 4124, 7075-T73 and T7351 bar, rod and wire (ANSI catalogue) webstore.ansi.org

Standards and rules are cited as references. Nothing here says that a part, a shop or this site meets them. Confirm the current text with the issuer. Not legal advice. Last reviewed November 28, 2026.

Does your drawing cite this?

Say so on the RFQ. We quote the finished parts and reply within 24 business hours, or tell you plainly if we cannot make it.

Send your RFQ